Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Int Braz J Urol ; 50(3): 250-260, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598828

RESUMO

BACKGROUND: Success rates in endourological procedures, notably percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), have demonstrated suboptimal outcomes, leading to more reinterventions and radiation exposure. Recently, the use of intraoperative computed tomography (ICT) scans has been hypothesized as a promising solution for improving outcomes in endourology procedures. With this considered, we conducted a comprehensive systematic review and meta-analysis encompassing all available studies that evaluate the impact of the use of intraoperative CT scans on surgical outcomes compared to conventional fluoroscopic-guided procedures. METHODS: This systematic review was conducted in accordance with PRISMA guidelines. Multiple databases were systematically searched up to December of 2023. This study aimed to directly compare the use of an ICT scan with the standard non-ICT-guided procedure. The primary endpoint of interest was success rate, and the secondary endpoints were complications and reintervention rates, while radiation exposure was also evaluated. Data extraction and quality assessment were performed following Cochrane recommendations. Data was presented as an Odds ratio with 95%CI across trials and a random-effects model was selected for pooling of data. RESULTS: A comprehensive search yielded 533 studies, resulting in the selection of 3 cohorts including 327 patients (103 ICT vs 224 in non-ICT). Primary outcome was significantly higher in the experimental group versus the control group (84.5% vs 41.4% respectively, 307 patients; 95% CI [3.61, 12.72]; p<0.00001; I2=0). Reintervention rates also decreased from 32.6% in the control to 12.6% in the ICT group (OR 0.34; 95%CI [0.12,0.94]; p =0.04; I2= 48%), whereas complication rates did not exhibit significant differences. Radiation exposure was also significantly reduced in two of the included studies. CONCLUSION: This meta-analysis highlights a favorable outcome with intraoperative CT scan use in PCNL procedures, showing a considerable increase in SFR when compared to standard fluoroscopy and nephroscopy. Despite limited studies, our synthesis underscores the potential of ICT scans to significantly reduce residual stones and their consequences for endourology patients, as reinterventions and follow-up ionizing radiation studies.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Cálculos Renais/etiologia , Nefrolitotomia Percutânea/métodos , Rim , Ureteroscopia/métodos , Tomografia , Resultado do Tratamento
2.
World J Urol ; 42(1): 159, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488875

RESUMO

PURPOSE: We aimed to assess whether the presence of contaminants in the pre-operative urine culture (preop-UC) predicts postoperative urinary tract infection (postop-UTI) in patients undergoing elective ureteroscopy with laser lithotripsy. METHODS: A retrospective chart review was performed from 01/2019 to 12/2021 examining patients with unilateral stone burden ≤ 2 cm who underwent ureteroscopy with laser lithotripsy and had a preop-UC within 3 months. Positive, negative, contaminated, and polymicrobial definitions for UCs were established in accordance with current guidelines. Patients with positive and polymicrobial cultures were excluded. Postop-UTI was defined as the presence of urinary symptoms and a positive UC within 30 days of the procedure. Multivariable logistic regression models were utilized to evaluate risk factors for contamination in the preop-UC and the risk of postop-UTI. RESULTS: A total of 201 patients met the inclusion-exclusion criteria. Preop-UC was negative in 153 patients and contaminated in 48 patients. Significant contaminant-related factors included female gender and increased BMI. Postop-UTI was diagnosed in 3.2% of patients with negative preop-UCs and 4.2% of patients with contaminants, with no difference between groups (p = 0.67). The regression model determined that the presence of contaminants in preop-UC failed to predict postop-UTI (OR 0.69, p = 0.64). CONCLUSION: The presence of contaminants in preop-UCs is not associated with an increased risk of postop-UTIs after ureteroscopy. Our study supports that contaminants in the preop-UC can be interpreted as a negative UC in terms of postop-UTI risk stratification. Preoperative antibiotics should not be prescribed for patients undergoing uncomplicated ureteroscopy for stone surgery in the setting of a contaminated preop-UC.


Assuntos
Ureteroscopia , Infecções Urinárias , Humanos , Feminino , Estudos Retrospectivos , Ureteroscopia/efeitos adversos , Ureteroscopia/métodos , Infecções Urinárias/epidemiologia , Infecções Urinárias/etiologia , Infecções Urinárias/tratamento farmacológico , Urinálise , Antibacterianos/uso terapêutico , Complicações Pós-Operatórias/etiologia
3.
Urology ; 183: 50-56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37951359

RESUMO

OBJECTIVE: To analyze the influence of different renal access angles (AAs) and nephroscope retrieval speeds on the efficacy of the vortex effect (VE) in mini-percutaneous nephrolithotomy (mini-PCNL). This study aimed to understand the poorly understood physical components of the VE. MATERIALS AND METHODS: A Pexiglas™ (KUS®) model was built based on the dimensions of a 15/16 F mini-PCNL set (Karl Storz). The flow rate was continuous via an automatic pump and calibrated to achieve hydrodynamic equivalence to the real equipment. One experiment consisted of manually retrieving all 30 stone phantoms (3 mm diameter) utilizing only the VE. Cumulative time to retrieve all stones was measured. An accelerometer recorded instant speeds of the nephroscope every 0.08 seconds (s), and 3 experiments were performed at each angle (0°, 45°, and 90°). A logistic regression model was built utilizing maximum speeds and access angles to predict the effectiveness of the VE. RESULTS: Mean cumulative time for complete stone retrieval was 28.1 seconds at 0° vs 116.5 seconds at 45° vs 101.4 seconds at 90° (P < .01). We noted significantly higher speeds at 0° compared to 45° and 90° (P < .01); however, differences in average and maximum speed between 45° and 90° were not statistically significant (P = .21 and P = .25, respectively). The regression model demonstrated a negative association between increasing maximum speed and VE's effectiveness (OR 0.547, CI 95% 0.350-0.855, P < .01). When controlling for maximum speed, the 0° angle had significantly higher chances of achieving at least a partially effective VE. CONCLUSION: Increasing the renal access angle or nephroscope extraction speed negatively impacts the effectiveness of the VE. This significantly increased procedure time in the laboratory model, suggesting that the VE is less effective at higher sheath angles.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Humanos , Cálculos Renais/cirurgia , Nefrostomia Percutânea/métodos , Rim , Endoscopia , Nefrolitotomia Percutânea/métodos , Resultado do Tratamento
4.
Urolithiasis ; 51(1): 101, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37561200

RESUMO

BACKGROUND: Cystine stone is a Mendelian genetic disease caused by SLC3A1 or SLC7A9. In this study, we aimed to estimate the genetic prevalence of cystine stones and compare it with the clinical prevalence to better understand the disease etiology. METHODS: We analyzed genetic variants in the general population using the 1000 Genomes project and the Human Gene Mutation Database to extract all SLC3A1 and SLC7A9 pathogenic variants. All variants procured from both databases were intersected. Pathogenic allele frequency, carrier rate, and affected rate were calculated and estimated based on Hardy-Weinberg equilibrium. RESULTS: We found that 9 unique SLC3A1 pathogenic variants were carried by 26 people and 5 unique SLC7A9 pathogenic variants were carried by 12 people, all of whom were heterozygote carriers. No homozygote, compoun d heterozygote, or double heterozygote was identified in the 1000 Genome database. Based on the Hardy-Weinberg equilibrium, the calculated genetic prevalence of cystine stone disease is 1 in 30,585. CONCLUSION: The clinical prevalence of cystine stone has been previously reported as 1 in 7,000, a notably higher figure than the genetic prevalence of 1 in 30,585 calculated in this study. This suggests that the etiology of cystine stone is more complex than what our current genetic knowledge can explain. Possible factors that may contribute to this difference include novel causal genes, undiscovered pathogenic variants, alternative inheritance models, founder effects, epigenetic modifications, environmental factors, or other modifying factors. Further investigation is needed to fully understand the etiology of cystine stone.


Assuntos
Sistemas de Transporte de Aminoácidos Básicos , Cistina , Cistinúria , Humanos , Sistemas de Transporte de Aminoácidos Básicos/genética , Cistina/metabolismo , Cistinúria/genética , Frequência do Gene , Genética Populacional , Mutação
5.
Urology ; 180: 74-80, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37482100

RESUMO

OBJECTIVE: To describe the physical principles of the vortex effect to better understand its applicability in minimally invasive percutaneous nephrolithotomy (MIP) procedures. METHODS: Two acrylic phantom models were built based on the cross-sectional area (CSA) ratio of a MIP nephroscope and access sheaths (15/16F and 21/22F MIP-M, Karl Storz). The nephroscope phantom was 10 mm in diameter. The access sheaths had diameters of 14 mm (CSA ratio: 0.69) and 20 mm (CSA ratio: 0.30). The models were adapted to generate hydrolysis, and hydrogen bubbles enhanced flow visualization on a green laser background. After calibration, the experimental flow rate was set to 12.0 mL/s. Three 30-second trials assessing the flow were performed with each model. Computational fluid dynamic simulations were completed to determine the speed and pressure profiles. RESULTS: In both models, as the incoming fluid from the nephroscope phantom attempted to move toward the collecting system, a stagnation point was demonstrated. No fluid entered the collecting system phantom. Utilizing the 14 mm sheath, we observed a random generation of several vortices and a pressure gradient (PG) of 114.4 N/m2 between the nephroscope's tip and stagnation point. In contrast, examining the 20 mm sheath revealed a significantly smaller PG (19.4 N/m2) and no noticeable vortices were noted. CONCLUSION: The speed of the fluid and equipment geometry regulate the PG and the vortices field, which are responsible for the production of the vortex effect. Considering the same flow rate, a higher ratio between the CSA of the nephroscope and access sheath results in improved efficacy of the vortex effect.

6.
Investig Clin Urol ; 64(3): 265-271, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37341006

RESUMO

PURPOSE: Holmium:YAG laser lithotripsy requires high amperage power and has an upper limit of frequency and a minimal fiber size. The technology utilizing thulium-doped fiber offers low pulse energy settings and high pulse frequencies up to 2,400 Hz. We compared the novel SuperPulsed thulium fiber laser (SOLTIVE™; Olympus) to a commercially available 120 W Ho:YAG laser. MATERIALS AND METHODS: Bench-top testing was conducted with 125 mm3 standardized BegoStones (Bego USA). Time to ablate the stone into particles <1 mm was recorded for efficiency calculations. Finite energy was delivered, and resulting particle sizes were measured to determine fragmentation (0.5 kJ) and dusting (2 kJ) efficiencies. Remaining mass or number of fragments were measured to compare efficacy. RESULTS: SOLTIVE™ was faster at ablating stones to particles <1 mm (2.23±0.22 mg/s, 0.6 J 30 Hz short pulse) compared to Ho:YAG laser (1.78±0.44 mg/s, 0.8 J 10 Hz short pulse) (p<0.001). Following 0.5 kJ of energy in fragmentation testing, fewer particles >2 mm remained using SOLTIVE™ than Ho:YAG laser (2.10 vs. 7.20 fragments). After delivering 2 kJ, dusting (1.05±0.08 mg/s) was faster using SOLTIVE™ (0.1 J 200 Hz short pulse) than 120 W 0.46±0.09 mg/s (0.3 J 70 Hz Moses) (p=0.005). SOLTIVE™ (0.1 J 200 Hz) produced more dust particles <0.5 mm (40%) compared to 24% produced by the P120 W laser at 0.3 J 70 Hz Moses and 14% at 0.3 J 70 Hz long pulse (p=0.015). CONCLUSIONS: The efficacy of SOLTIVE™ is superior to the 120 W Ho:YAG laser by producing smaller dust particles and fewer fragments. Further studies are warranted.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Túlio , Hólmio
7.
World J Urol ; 41(2): 575-579, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36607392

RESUMO

PURPOSE: As part of the management of nephrolithiasis, determination of chemical composition of stones is important. Our objective in this study is to assess urologists' accuracy in making visual, intraoperative determinations of stone composition. MATERIALS AND METHODS: We conducted a REDCap survey asking urologists to predict stone composition based on intraoperative images of 10 different pure-composition kidney stones of 7 different types: calcium oxalate monohydrate (COM), calcium oxalate dihydrate (COD), calcium phosphate (CP) apatite, CP brushite, uric acid (UA), struvite (ST) and cystine (CY). To evaluate experience, we examined specific endourologic training, years of experience, and number of ureteroscopy (URS) cases/week. A self-assessment of ability to identify stone composition was also required. RESULTS: With a response rate of 26% (366 completed surveys out of 1,370 deliveries), the overall accuracy of our cohort was 44%. COM, ST, and COD obtained the most successful identification rates (65.9%, 55.7%, and 52.0%, respectively). The most frequent misidentified stones were CP apatite (10.7%) and CY (14.2%). Predictors of increased overall accuracy included self-perceived ability to determine composition and number of ureteroscopies per week, while years of experience did not show a positive correlation. CONCLUSIONS: Although endoscopic stone recognition can be an important tool for surgeons, it is not reliable enough to be utilized as a single method for stone identification, suggesting that urologists need to refine their ability to successfully recognize specific stone compositions intraoperatively.


Assuntos
Cálculos Renais , Cálculos Urinários , Humanos , Urologistas , Cálculos Renais/cirurgia , Estruvita , Apatitas , Oxalato de Cálcio , Cistina , Cálculos Urinários/química
8.
J Endourol ; 37(1): 99-104, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36106599

RESUMO

Purpose: Digital ureteroscopes employ "chip-on-the-tip" technology that allows for significant improvement in image resolution. However, image distortion often occurs during laser lithotripsy owing to acoustic wave production. We sought to compare image distortion using different laser power settings and distances from the laser fiber tip to the scope for the Super Pulsed Thulium Fiber (SPTF) laser and high-power Holmium:YAG (Ho:YAG) laser. Materials and Methods: Ureteroscopy was simulated using a silicon kidney-ureter-bladder model fitted with a 12F/14F access sheath and the Lithovue™ (Boston Scientific), disposable digital flexible ureteroscope. At defined laser parameters (10, 20, 30 and 40 W, short pulse), a 200-µm laser fiber was slowly retracted toward the tip of the ureteroscope during laser activation. Image distortion was identified, and distance from the laser tip to the scope tip was determined. Data from the two lasers were compared utilizing t-tests. Results: After controlling for frequency, power, and laser mode, utilizing 1.0 J of energy was significantly associated with less feedback than 0.5 J (-0.091 mm, p ≤ 0.05). Increased power was associated with larger feedback distance (0.016 mm, p ≤ 0.05); however, increase in frequency did not have a significant effect (-0.001 mm, p = 0.39). The SPFT laser had significantly less feedback when compared with all Holmium laser modes. Conclusions: Increased total power results in image distortion occurring at greater distances from the tip of the ureteroscope during laser activation. Image distortion occurs further from the ureteroscope with Ho:YAG laser than with SPTF fibers at the same laser settings. In clinical practice, the tip of the laser fiber should be kept further away from the tip of the scope during ureteroscopy as the power increases as well as when utilizing the Ho:YAG system compared with the SPTF laser platform. The SPTF laser may have a better safety profile in terms of potential scope damage.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Hólmio , Litotripsia a Laser/métodos , Túlio , Ureteroscópios , Ureteroscopia
9.
Urology ; 173: 68-74, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36400269

RESUMO

OBJECTIVE: To compare the maintenance costs of digital flexible ureteroscopes (DFU) versus fiberoptic flexible ureteroscopes (FFU) to understand the long-term financial impact associated with breakage in a flexible ureteroscopy (f-URS) program. METHODS: Data for breakage of FFU and DFU at an academic institution from 2019 to 2021 were obtained from our vendor (Karl Storz) and analyzed by month. Correlation test was used to evaluate significant differences in number of procedures, number of breakage events, breakage rates, and repair cost per month. Cumulative analyses were utilized to examine the number of procedures before failure (time to failure - TTF) and repair costs per procedure (RCpP). RESULTS: We performed a total of 2,154 f-URS, including 1,355 with FFU and 799 with DFU (P<.001). Although we found a higher number of breakage events in FFU (n=124) than DFU (n=73) (P<.001), the overall breakage rate was similar, 9.9% vs. 8.8%, respectively (P=0.86). On cumulative analysis, both modalities reached the same TTF plateau (11 cases) after 18 months. After 400 cases, the RCpP for DFU was 1.25 times higher than for FFU (P=0.04). CONCLUSION: Overall, we found no difference in overall scope breakage rates between DFU and FFU. Although there was no difference in TTF over time, at the beginning DFU displayed considerable higher durability, leading to lower RCpP. Furthermore, DFU's endurance leveled off to FFU over time, resulting in higher RCpP after 400 cases. This finding may be explained by the presence of renewed scopes after repair.


Assuntos
Ureteroscópios , Ureteroscopia , Humanos , Ureteroscopia/métodos , Tecnologia de Fibra Óptica , Desenho de Equipamento
11.
Urology ; 153: 87-92, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33621583

RESUMO

OBJECTIVE: To report the first case series of ureterorenoscopy in North America using the High Power Super Pulse Thulium Fiber Laser for the treatment of upper urinary tract stones. METHODS: After Institutional Review Board approval, a multicentric retrospective chart review of patients treated with the High Power Super Pulse Thulium Fiber Laser from October 2019 to March 2020 was conducted. Basic demographic information, pre-operative, and peri-operative data were recorded. RESULTS: Seventy-six patients were included with a mean age of 60.9 ± 13.3 years. 118 stones were treated including 32 within the ureter, 49 in the lower pole, 37 in mid or upper poles. Dusting technique was commonly used (67.1%) with pulse frequencies up to 2400 Hz. Mean operative time was 59.4 ± 31.5 minutes. Mean laser time and total laser energy were 10.8 ± 14.1 minutes and 12.5 ± 19.1 KJ, respectively. Intraoperative complications were limited to 7 grade 1, 3 grade 2, and 1 grade 3 ureteral injuries and one case of renal collecting system bleeding that was adequately managed with laser coagulation settings (1J-20Hz). CONCLUSION: This initial case series in North America of the High Power Super Pulse Thulium Fiber Laser is promising for the treatment of urolithiasis. Sub-200 µm fibers and dusting settings up to 2400 Hz were utilized successfully. No specific complications related to use of the laser were seen.


Assuntos
Cálculos Renais/terapia , Litotripsia a Laser/métodos , Túlio/uso terapêutico , Cálculos Ureterais/terapia , Ureteroscopia/métodos , Canadá , Feminino , Humanos , Litotripsia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Estados Unidos , Ureteroscopia/efeitos adversos
12.
World J Urol ; 39(10): 3951-3956, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33604733

RESUMO

PURPOSE: The holmium-YAG (Ho:YAG) Laser system is the current gold standard for laser lithotripsy (LL). Super Pulse Thulium Fiber Laser (SPTF) has emerged as an effective alternative. We compared the temperature profile of both the 120 W Ho:YAG and the 60 W SPTF systems during ureteral lithotripsy. METHODS: Antegrade ureteroscopy with LL was performed in ex-vivo porcine kidneys with 3 mm Begostones. Intra-ureteral temperature was measured using one probe proximal and one distal to the site of lithotripsy. LL was performed using a 200 µm core fiber at dusting (SPTF-0.1 J, 200 Hz, SP; Ho:YAG-0.3 J, 70 Hz, LP) and fragmenting (0.8 J, 8 Hz, SP for both) settings for 5 s. Fifteen repetitions were recorded for each laser at each setting. Tissue samples of the ureter were collected for histological analysis. RESULTS: There was a rise in temperature at the site of lithotripsy using both systems at every setting evaluated. The median temperatures were greater for the SPTF on the fragmenting setting (33.3 °C vs 30.0 °C, p = 0.004). On the dusting setting, the median temperature was not statistically greater for Ho:YAG (40.6 °C vs 35.8 °C, p = 0.064), (Graphic 1). Histological analysis did not show any signs of injury or necrosis in any of the tested settings. CONCLUSION: Higher power settings used for dusting have a higher temperature rise in the ureter during lasering. Median ureteral intra-luminal temperature rise during LL was equivalent during dusting and higher in the SPTF during fragmentation, but neither reached the threshold for thermal injury based on the duration of exposure.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser/instrumentação , Temperatura , Túlio , Ureter/patologia , Cálculos Ureterais/terapia , Animais , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Suínos , Ureter/lesões
13.
World J Urol ; 39(9): 3587-3591, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33512571

RESUMO

PURPOSE: Basketing plays an important role during flexible ureteroscopy, but it can be time-consuming, especially when fragments are too large to pass through the ureteral access sheath. We aim to present the optimal on-screen, endoscopic stone size that predicts successful basketing through various access sheaths. METHODS: A tipless basket, individually extended to 5 mm from multiple ureteroscopes: (Flex-Xc, Karl Storz; Flex-X2s, Karl Storz; LithoVue, Boston Scientific; or URF-P6R, Olympus) and via differently sized access sheaths (10-12 Fr through 13-15 Fr), was used in retrieval attempts of various artificial stone sizes (2 mm through 5 mm). A relative endoscopic stone size was recorded as the stone's maximum diameter on endoscopic view compared to the total image diameter. RESULTS: Basketing of stones up to 2.5 mm, yielding relative endoscopic stone sizes of 0.38 (Flex-Xc), 0.30 (Flex-X2s), 0.32 (LithoVue), and 0.34 (URF-P6R), was successful using all access sheaths. Only the 12-14 Fr and greater sheaths allowed for successful basketing of 3 mm stones. Larger stones did not successfully pass through any of the access sheaths. CONCLUSION: Successful stone retrieval can be predicted by estimating the stone's size on screen, which is influenced by the type of flexible ureteroscope and access sheath. In our testing, stones of approximately one-third of the screen size passed successfully in all cases.


Assuntos
Modelos Anatômicos , Ureteroscópios , Ureteroscopia , Cálculos Urinários/patologia , Cálculos Urinários/cirurgia , Valor Preditivo dos Testes , Resultado do Tratamento
14.
Urology ; 149: 187-192, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33412223

RESUMO

OBJECTIVE: To determine if MOSES technology improves efficiency and short-term outcomes in holmium laser ablation of the prostate (HoLAP). METHODS: A retrospective review of patients who underwent HoLAP between August 2016 and November 2019 was conducted. All procedures before and after the implementation of MOSES technology at our institution were evaluated. Preoperative patient characteristics and intraoperative data were collected. Postoperative International Prostate Symptom Score, quality of life, and postvoid residual measurements at 6 weeks and 3 months postoperatively were analyzed. RESULTS: This cohort included 65 males who underwent HoLAP, 32 without and 33 with MOSES. Patients in the MOSES group were slightly older, but no other differences in baseline characteristics were observed between the two groups. Ablation time was similar at 49.6 ± 26.1 minutes without and 40.7 ± 41.2 minutes with MOSES (P = .38). However, HoLAP with MOSES had significantly higher ablation efficiency (0.59 ± 0.24 g/min without vs 0.86 0.5 g/min with MOSES, P = .01). On multivariable regression modeling, HoLAP without MOSES added 12 minutes to operating time (estimate 12.3, standard error 3.44, P < .01) after controlling for prostate size and laser energy usage. Duration of catheterization, urinary incontinence and need for reoperation within 3 months were similar. There were no differences between groups in International Prostate Symptom Score, quality of life, or postvoid residual at 3 months postoperatively. CONCLUSION: Utilization of MOSES technology resulted in improved efficiency in HoLAP, translating into time savings in the operating room. Postoperative outcomes out to 3 months were similar among patients who underwent the procedure utilizing either laser pulse mode. Further studies are needed to investigate long-term outcomes as the use of MOSES is likely to become more commonly utilized.


Assuntos
Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Sintomas do Trato Urinário Inferior/cirurgia , Prostatectomia/métodos , Hiperplasia Prostática/cirurgia , Idoso , Humanos , Terapia a Laser/instrumentação , Terapia a Laser/estatística & dados numéricos , Sintomas do Trato Urinário Inferior/etiologia , Sintomas do Trato Urinário Inferior/psicologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Próstata/patologia , Próstata/cirurgia , Prostatectomia/instrumentação , Prostatectomia/estatística & dados numéricos , Hiperplasia Prostática/complicações , Hiperplasia Prostática/patologia , Qualidade de Vida , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
17.
Clin Genitourin Cancer ; 15(5): 513-519.e5, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28442227

RESUMO

The objective of this study was to compare the surgical, oncological, and functional outcomes of laparoscopic and percutaneous cryoablation for the treatment of small renal masses. A systematic review of the literature was performed through March 2016 using PubMed, Scopus, and Ovid databases. Article selection proceeded according to the search strategy on the basis of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. Only studies that compared laparoscopic and percutaneous kidney cryoablation were included in the meta-analysis. Eleven retrospective comparative studies were identified and selected for the analysis, including 1725 cases: 804 (46.6%) percutaneous and 921 (53.4%) laparoscopic cryoablations. Percutaneous cryoablation was performed more frequently for posterior tumors (P < .001), whereas laparoscopy was more common for endophytic lesions (P = .01). The length of follow-up was longer for laparoscopy (P < .001). Percutaneous cryoablation was associated with a significantly shorter hospital stay (P < .001). A lower likelihood of residual disease was recorded for laparoscopic (P = .003), whereas tumor recurrence rate favored percutaneous cryoablation (P = .02). The 2 procedures were similar for recurrence-free survival (P = .08), and overall survival (P = .51). No significant difference was found in postoperative estimated glomerular filtration rate (P = .78). Laparoscopic and percutaneous kidney cryoablation offer similar favorable oncological outcomes with minimal effect on renal function. The percutaneous access can offer shorter hospital stay and faster recovery, which can be appealing in an era of cost restraint.


Assuntos
Criocirurgia/métodos , Neoplasias Renais/cirurgia , Laparoscopia/métodos , Feminino , Humanos , Tempo de Internação , Masculino , Análise de Sobrevida , Resultado do Tratamento
18.
Patient Saf Surg ; 11: 10, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28396695

RESUMO

BACKGROUND: Approximately 12% of all ureteral stents placed are retained or "forgotten." Forgotten stents are associated with significant safety concerns as well as increased costs and legal issues. Retained ureteral stents (RUS) often occur due to lack of clinical follow-up, communication or language barriers, and economic concerns. METHODS: We describe a multiplatform application that facilitates data collection to prevent RUS. The "Stent Tracker" application can be installed on mobile devices and computers. The encrypted and password-protected information is accessible from any device and provides information about each procedure, stent placement and removal dates, as well as product description. This multicenter retrospective study included 194 patients who underwent stent placement between July and October 2015. Nominal data was tallied and ordinal data was divided into quartiles of 25, 50, and 75%. RESULTS: A total of 194 patients from three institutions underwent ureteral stent placement. Reasons for stent placement include 122 cases post ureteroscopy (63%), 8 cases post percutaneous nephrolithotomy (PCNL) (4%), 14 cases post extracorporeal shock wave lithotripsy (SWL) (7%), 18 cases of cancer-related ureteral obstruction (9%), 21 cases of hydronephrosis (11%), and 11 for other reasons (6%). Of these patients, only one patient was lost to follow-up (0.5%). On average, ureteral stents were removed within 14 days of placement (IQR: 8-26 days). CONCLUSIONS: The "Stent Tracker" is a patient safety application that provides a secure and simplified interface, which can significantly reduce the incidence of RUS. Further developments could include automated notifications to patients and staff, color-coding, and integrated information with electronic patient charts.

19.
Can J Urol ; 23(4): 8385-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27544565

RESUMO

Subcapsular hematoma is an uncommon complication after ureteroscopy and laser lithotripsy. We report on a 38-year-old male with an 8 mm lower pole stone who underwent a left ureteroscopy and laser lithotripsy. The stone was successfully fragmented. Several hours after being discharged home, the patient returned complaining of back pain and hematuria. He was hemodynamically stable. Laboratory exams were normal. A CT study showed a crescent renal subcapsular hematoma surrounding the left kidney. The patient was admitted to the ward for conservative treatment. No additional intervention was necessary. Most subcapsular hematomas tend to resolve spontaneously.


Assuntos
Hematoma , Rim/diagnóstico por imagem , Litotripsia a Laser/efeitos adversos , Hemorragia Pós-Operatória , Ureterolitíase/cirurgia , Ureteroscopia/efeitos adversos , Adulto , Drenagem/métodos , Hematoma/diagnóstico , Hematoma/etiologia , Hematoma/fisiopatologia , Hematoma/terapia , Humanos , Litotripsia a Laser/métodos , Masculino , Medição da Dor/métodos , Hemorragia Pós-Operatória/diagnóstico , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/fisiopatologia , Hemorragia Pós-Operatória/terapia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Ureterolitíase/diagnóstico , Ureterolitíase/fisiopatologia , Ureteroscopia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...